What Is the 80% Rule for Breakers?
What this costs
| Option | Job | Low | High |
|---|---|---|---|
| Replace | Electrical Panel Upgrade | $1,000 | $3,150 |
The math for common home breakers
This is our own arithmetic from Schneider's 80% figure. Schneider's FAQ names its PowerPact and Masterpact frames, so applying it to home breakers is our own reading. Volts assume a standard 120-volt circuit.
- 15-amp breaker: 12 amps continuous, about 1,440 watts.
- 20-amp breaker: 16 amps continuous, about 1,920 watts.
- 30-amp breaker: 24 amps continuous.
What counts as continuous
Schneider says the National Electrical Code treats a load of 3 hours or more as continuous. Our own examples of what runs that long on one circuit: a space heater overnight or a car charger. By the same definition, a microwave running for a few minutes isn't a continuous load, though we'd count it toward the total while it runs.
What this rule doesn't mean
It doesn't mean your breaker trips at 80%. It's a sizing limit for long-running loads, and a breaker can run at its full rating for shorter periods. Schneider also notes that some breakers can be applied at up to 100% continuously, and it lists specific frames with a special suffix.
If you keep hitting the limit
Never swap in a larger breaker to stop trips. CPSC warns that overrated fuses or breakers allow overloading that can lead to fire. We recommend moving long-running loads to another circuit, or having a licensed electrician add a circuit. We recommend an electrician for panel work, and we don't give steps for it.
Breaker Keeps Tripping? Causes and When to Call
Common questions
How many amps can I put on a 15-amp breaker?
How do I find out what my appliance draws?
Related questions
- Are GFCI Outlets Required in a Garage?
- Can a Breaker Go Bad Without Tripping?
- Can a Light Switch Cause a Breaker to Trip?
- Can a Roof Leak Be Fixed From the Inside?
- Can a Water Heater Leak Carbon Monoxide?
- Can Breakers Trip for No Reason?
- Can Garage Door Springs Kill You?
- Can GFCI Outlets Go Bad?
Last verified 2026-11-04
- Schneider Electric: 80% and 100% rated breakers FAQ — Standard-rated breaker applied at 80 percent of rating for continuous loads of 3 hours or more; 100 percent for shorter periods; 100 percent rated breakers exist.
- U.S. Consumer Product Safety Commission: Home Wiring Hazards publication 518 (undated older guide) — Don't put in a higher ampere fuse or breaker; overrated devices can lead to overloading and fire; get a qualified electrician.
- University of Washington EH&S: Circuit breakers (April 2022, workplace guidance for campus staff, not a home rule) — Warning signs of overloaded circuits and high-draw appliances.
General information, not professional advice. Conditions, codes and prices vary. Turn off power, gas or water before any work, and hire a licensed professional when in doubt. Cost figures are our estimates, not quotes.